Substations
Stator Core Measurement Upgrade Option
• Semi-automatic scanning of the stator core
• Measurement and excitation in one solution
• Frequency-variable injection from 15 to 400 Hz
• User-friendly work flow using Primary Test Manager (PTM) software
• Automated reporting including results, graphs and heat map
• Easily extendable excitation cable to meet specific measurement requirements
• Measurement and excitation in one solution
• Frequency-variable injection from 15 to 400 Hz
• User-friendly work flow using Primary Test Manager (PTM) software
• Automated reporting including results, graphs and heat map
• Easily extendable excitation cable to meet specific measurement requirements
RIV1
• Adjustable signal frequency and output voltage to match application requirements
• Application-specific versions of RIV calibrators and measurement impedances ensure fully compliance to applicable measurement standards
• Complies with all parts of RIV related NEMA, IEEE, IEC and CISPR standards
• Independent power supply with built-in battery
• Application-specific versions of RIV calibrators and measurement impedances ensure fully compliance to applicable measurement standards
• Complies with all parts of RIV related NEMA, IEEE, IEC and CISPR standards
• Independent power supply with built-in battery
CMC 256plus
• Protection test set and universal calibrator in one device
• Testing of all relay generations – electromechanical, static, numerical, IEC 61850
• Highly accurate test signals. For meter testing: The sources are the reference – no additional reference meters are required
• Integrated network for testing IEC 61850 IEDs
• 10-channel analog measurement and transient recording functionality (option)
• Testing of all relay generations – electromechanical, static, numerical, IEC 61850
• Highly accurate test signals. For meter testing: The sources are the reference – no additional reference meters are required
• Integrated network for testing IEC 61850 IEDs
• 10-channel analog measurement and transient recording functionality (option)
CMS 356
• Six analog low-level inputs with selectable range (±7.07 Vpk or ±10 Vpk)
• Numerous output configurations, for example, 3 x 300 V + 3 x 64 A or 6 x 32 A
• Calculation and output of residual voltage and current
• Parallel connection of several CMS 356 units for even higher current amplitudes
• All current and voltage outputs are fully overload and short circuit proof
• Protection against voltage transient signal and over temperature
• Numerous output configurations, for example, 3 x 300 V + 3 x 64 A or 6 x 32 A
• Calculation and output of residual voltage and current
• Parallel connection of several CMS 356 units for even higher current amplitudes
• All current and voltage outputs are fully overload and short circuit proof
• Protection against voltage transient signal and over temperature
Submit your product request directly and our staff will contact you to provide you with all relevant information.
Why choose our products?
- High quality
- Resistant to external factors
- Competitive price
