Substations

MONGEMO

• Customized system approach to match specific monitoring requirements
• Synchronous, four-channel PD data acquisition for complete PD assessment
• Advanced noise suppression and fully automated PD cluster separation for convenient evaluation
• Recording of raw PD data at selected intervals for in-depth post analysis
• Seamless integration with third-party monitoring devices and SCADA systems 

PDL 650

• Efficient because repairs and spare parts are predictable when failure location is known
• Easy creation of reports and records
• Safe due to galvanic separation of operator from high-voltage
• Convenient and handy through light weight, small size and battery operation

VOTANO 100

• For voltage transformer testing (VT/CVT):
• Check the electrical performance of VTs and CVTs
• Check the condition of VTs and CVTs
• Basic condition assessment for CVTs 
• Tests such as ratio, phase, polarity, capacitive ratio
• Additionally, for voltage transformer accuracy verification and calibration (VT/CVT):
• Verify accuracy class according to IEC, IEEE
• Test of VTs/CVTs up to rated voltages and voltage factors up to 1.9

CB MC2

• Dynamic contact resistance test
• High-current cables are kept as short as possible (weight reduction)
• Low interference due to the digital connection to CIBANO 500
• Fast test set up and reduced risk of wiring errors

CP CR600

• Maximum test voltage of 15 kV
• Easy to transport due to its modular and lightweight concept (48 kg / 106 lbs)
• Convenient and flexible test setup, ideal for test objects with limited access
• Low noise level, ideal for partial discharge measurements
• Several units can be connected in parallel

HGT1

• Mobile solution – simplifies measurements at various locations inside and outside the substation 
• Frequency-selective measurement for effective noise suppression
• Simulation of body and shoe resistance for step and touch voltage testing
• Even more powerful with Primary Test Manager™ (PTM)
• Fully automated due to GPS test point tracking and test current detection
• Real-time assessment of step and touch voltages according to EN 50522 or IEEE 80

IOB1

• Enables advanced timing tests in real time on circuit breakers with more than 6 auxiliary contacts and several trip and close coils without rewiring
• Makes sophisticated timing analyses possible such as CO sequence with overlapping trip/close coil operation
• Offers six input channels for real-time data transfer between 6 auxiliary contacts and CIBANO 500 (EtherCAT® communication)
• Offers six output channels for both control and analysis of CB trip or close coils or motors

UPG 620

• Bandwidth up to 2 GHz
• Smallest increment 0.5 V
• Easy to use
• Applications
• Checking the sensitivity of PD measuring circuits in gas-insulated switchgears (GIS), power transformers and power cables

Submit your product request directly and our staff will contact you to provide you with all relevant information.

Why choose our products?

  • High quality
  • Resistant to external factors
  • Competitive price

Request now