Guided radar measurement Time-of-Flight Levelflex FMP53

Process temperature
-20...+150 °C
(-4...+302 °F)
Process pressure absolute / max. overpressure limit
Vacuum...16 bar
(Vacuum...232 psi)
Max. measurement distance
Rod: 6 m (20 ft)
Min DK>1.6


Electronic differential pressure Deltabar FMD71

• Process temperature
–25...+150°C
(–13...+302°F)
• Pressure measuring range
100mbar...40bar
(1.5psi...600psi)
• Process pressure absolute / max. overpressure limit
60 bar (900 psi)
• Measuring cell
100 mbar...40 bar
(1.5 psi...600 psi)

Deltabar PMD55B - differential pressure transmitter

Process temperature
• -40°C…+110°C (-40°F... + 230°F)
Pressure measuring range
• 30 mbar.... 40 bar (0.45 psi... 600 psi)
Main wetted parts
• 316L, AlloyC
Material process membrane
• 316L, AlloyC
Measuring cell
• 30 mbar...40 bar
• (0.45 psi...600 psi)

Capacitance- Point level detection-Liquipoint FTW23

Process temperature
Standard:
• -20 ... 100°C
Cleaning:
• -20 ... 135°C for 1h
• -4 ... 275F for 1h
Process pressure absolute / max. overpressure limit
• Vacuum ... 16 bar
• Vacuum ....232 psi

Radar measurement-Micropilot FMR60

Accuracy
• +/- 1 mm (0.04 in)
Process temperature
• -40…+130 °C
• (-40…+266 °F)
Process pressure absolute / max. overpressure limit
• Vacuum …16 bar
• (Vacuum … 232 psi)
Max. measurement distance
• 50 m (164 ft)


Digital pH sensor-Orbisint CPS11D

Measurement range
  • pH 0 to 14
Process temperature
  • 0 to 135 °C (32 to 275 °F)
Process pressure
  • 1 to 17 bar (15 to 246 psi)

4-channel transmitter-Liquiline CM444

Input
• 1 to 4x Memosens digital input
• 2x 0/4 to 20mA Input optional
• 2 to 4x Digital input optional
Output / communication
• 2 to 8x 0/4 to 20 mA current outputs, alarmrelay,
• 4x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
Ingres protection
• IP66 / IP 67

Proline Promag P 300 - Electromagnetic flowmeter

Max. measurement error
• Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
• Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
Measuring range
• 4 dm³/min to 9600 m³/h (1 gal/min to 44 000 gal/min)
Medium temperature range
• Liner material PFA: –20 to +150 °C (–4 to +302 °F)
• Liner material PFA high-temperature: –20 to +180 °C (–4 to +356 °F)
• Liner material PTFE: –40 to +130 °C (–40 to +266 °F)



Dërgo direkt kërkesën tënde për produkte dhe stafi ynë do t'ju kontaktojë për t'ju dhënë të gjithë informacionin përkatës.

Përse të zgjidhni produktet tona?

  • Cilësi e lartë
  • Rezistent ndaj faktorëve të mjedisit
  • Çmim konkurues në treg

Porosit tani